ESAB MultiPower 460 Pulse Instrukcje Operacyjne Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
12
SECTION 2 INSTALLATION
IV. PULSE CONTROL PANEL INSTALLATION
The standard MultiPower 460 control panel are easily removed and replaced
with the MultiPower 460 Pulse version using the following procedure. Refer to
Figure 4-1.
Step 1. Disconnect ALL primary power from the MultiPower 460 by unplug-
ging the unit or removing the line fuses.
Step 2. Remove the four screws (one at each corner) holding the standard
MultiPower 460 control panel in place.
Step 3. Tilt the panel forward and disconnect the wiring harness plug connec-
tor and remove the control panel from the PC board compartment. Do
not discard this panel is can be used as a spare replacement panel if
problems arise.
Step 4 Connect the NEW MultiPower 460 Pulse control panel harness plug
to the power source harness.
Step 5. Carefully position the control panel over the PC board compartment
and secure with the mounting screws removed from the standard
control panel.
Panel Screws
Panel Harness Plug
Figure 4-1 MultiPower 460 Pulse Harness Connection
Przeglądanie stron 11