48
SECTION 5 MAINTENANCE
Figure 5-7. Ammeter Displays 760A
Figure 5-6. PRESET Does Not Function
Preset does
not function
(unit welds)
Does preset work when
P2-11 and P216
(PCB1) are jumpered?
Replace
Switch S4
Replace
PCB1
Yes
No
Yes
1-Unit is in Stick Mode
2-CCP is set to minimum
4-Output leads are not shorted
3- Panel/Remote is in "Panel"
Ammeter
Displays
760 amps
Verify
Is voltage at
OTB + to OTB - =
to 80 VDC
Is Voltage at
(PCB1)
P1-7 to P1-2 = > 7
VDC
Is Voltage at
(PCB-1)
P3-2 to P3-4 =
> 7VDC
Is Voltage at
(SH-1)
3 to 4 =
> 7VDC
Replace SH-1
Check Wiring
Replace
PCB-1
Is
OTB- + to OTB -
shorted
Repair short
circuit
No
Yes
Yes
No
No
Yes
No
No
Yes