SECTION 5 MAINTENANCE
C2 E1
E2
C1
G2
E2
Set the VOM to ohms then check for continuity between all the legs of the IGBT. No continuity should be measured. Place
the red probe to the Collector (C1) and the black probe to the Emitter ( E1). The VOM should read very high resistance or an
open circuit. No shorts (continuity) should be measured. Repeat the steps on the second IGBT pair (C2 E2). This ensures
the IGBT is turned o.
Insulated Gate Bipolar Transistor (IGBT)
C2 E1
E2
C1
G2
E2
-
+
Place a DC power source (9 v battery) on the gate leads of the same IGBT. First the negative source on the gate with the
positive source on the emitter. This should not change the meter reading. Next place the positive source on the gate and
the negative source on the emitter. This should turn on the IGBT.
NOTE
The power source should be more the
6 volts and less than 20. A 9 volt bat-
tery is common and works quite well.