Check the voltage links for proper volt-
age on the Input Terminal board before
applying primary power.
5. Figure 3-3 illustrates the input voltage terminal boards and the input voltage link connections. The
particular voltages from which this power source may be operated are stated on the rating plate. The
voltage links were factory set for highest voltage stated on the rating plate (575VAC). If the power source
is to be operated on another stated input voltage, the links must be reset for that particular input voltage.
Always verify the input voltage and check the link arrangement regardless of factory setting. The voltage
links are set up by reconfiguring the copper link bars to the silk-screened voltage designations for the
desired voltage.
Figure 3-3. Input Terminal Board Configuration for 230/460/575 Model
(factory supplied in the 575 configuration)
230 Vac Input 460 Vac Input 575 Vac Input