ESAB MultiPower 460 Pulse Instrukcja Obsługi Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
17
Figure 2-6. Remote Control Pendant
DESCRIPTION
SECTION 2
NOTE
If a Remote Control Pendant is used for
continuous current control, place the
PANEL/REMOTE switch in the PANEL
POSITION and set the Panel Current knob
to the maximum desired weld current. The
remote device will then control the current
between minimum and the maximum set-
ting preset (proportional current control).
Maximum Tig weld current is 525 amps.
NOTE
If the MP-460 PANEL/REMOTE switch
is left in the REMOTE position when Tig
welding while using a remote current
control device, the current range will
be full scale or 10 to 400 Amps.
Limiting the the Maximum weld current
on the MP-460 front panel is defeated.
NOTE
When using the MP-460 Pulse, the
STANDARD/PULSE switch must be in
the STANDARD position for proportional
current control using a TIG remote
current device.
E. OPTIONAL ACCESSORIES
1. REMOTE CONTROL PENDANT (PN - 0558002871)
This pendant (Figure 2-6) provides remote output control and a contactor
closure switch to close the contactor making the output terminals “hot”. The
PANEL/REMOTE switch on the MultiPower 460 Pulse control panel must be
placed in the REMOTE position when using this accessory. The pendant
has the capability to change weld processes as well as adapt to digital and
analog wire feeders.