The selectable pulse parameters are any combination of WIRE TYPE or WIRE
DIAMETER selected using the PULSE SELECTION switches. Not all combina-
tions will produce acceptable pulse characteristics but by using the pulse tables
provided in this manual, reasonable pulse combinations can be selected for trial.
This will take some trial and error but the added flexibility and expanded pulse
range of the non-synergic mode can be beneficial for many welding applications.
There are several unique advantages to Non Synergic pulse mig welding. The
Non -Synergic mode of operation permits pulse welding when:
1. A wire feeder without tachometer feedback is used.
2. An "Off the Arc" wire feeder is used
3. The Mig wire type or diameter installed on the wire feeder does not have
a pulse synergic line available..
4. Pulse arc characteristics other than those preprogrammed are desired.
To take advantage of the Multipower 460 Pulse Non-Synergic mode, it is
necessary to reposition a jumper plug and/or connector in the main control panel
wiring harness. Remove the Multipower 460 control panel and locate the jumper
plug in the wiring harness in the PC board compartment.
Jumper Plug Installed (Factory Shipped)
Synergic Mode - Pulse circuitry is looking for a 1 volt per 100 inches per minute
signal to determine the pulse parameters required to make the weld.
Figure 4-7 Jumper Plug Installed (Factory Shipped)
Jumper Plug Removed and Harness connected
Non-Synergic Mode - The pulse parameters are determined by the position of
the pulse selection switches, the Multipower 460PULSE TRIM knob and Wire
Feed Speed set on the wire feeder.
Figure 4-8 Jumper Plug Removed and Harness Connected